Combined Plate & Tube Laser
In stock5x10 3kW Plate & Tube Fiber Laser USA
Review the exact configuration, utilities, included equipment, options, delivery, installation, training, warranty, service, and parts pathway for this machine.
Final equipment, accessories, freight, taxes and field-service scope are confirmed in the written quote.
Material, geometry, capacity, production volume, quality, and workflow.
Model, controller, source or drive, tooling, included equipment, and options.
Power, air, gas, extraction, cooling, access, unloading, and placement.
Delivery, startup, training, warranty, service, parts, and acceptance.
Buyer fit
Match the machine to the real work
The best configuration depends on the actual parts, production target, available utilities, operator workflow, and complete delivered project.
Prepare these application details
- Material type, grade, thickness or capacity, dimensions, geometry, and drawings.
- Prototype, mixed job-shop, repeat production, automation, and throughput expectations.
- Required finish, accuracy, repeatability, tooling, consumables, and downstream work.
- Current voltage, phase, amperage, compressed air, process gas, extraction, and floor space.
Machine specifications
Technical and facility planning
Review the selected machine build, utilities, included equipment, and site requirements together before ordering.
- Model
- UCPT-5x10-3KW-T20FT-C8IN-BASE
- Machine family
- Combined Plate & Tube Laser
- Working area / capacity
- Defined in the written build sheet
- Power / tonnage
- Matched after application review
- Controller and axes
- Confirmed for the selected build
- Electrical requirements
- Confirmed after site and build review
- Machine dimensions
- Defined in the written build sheet
- Machine weight
- Defined in the written build sheet
- Lead time
- Confirm with sales
Included equipment
The written quote will identify the machine, controller, source or drive system, cooling, accessories, starter items, and other included equipment.
Available options
Options are selected for automation, material handling, extraction, gas, tooling, safety, utilities, production volume, and future expansion.
Site readiness
Plan the facility before delivery
Electrical service, utilities, extraction, access, unloading, placement, commissioning, and operator preparation are part of the machine project.
- Confirm voltage, phase, amperage, breaker, disconnect, grounding, and transformer requirements.
- Confirm compressed air, process gas, extraction, cooling, drainage, and environmental requirements.
- Confirm crate dimensions, machine weight, door and aisle clearance, dock, forklift, crane, and placement path.
- Complete the site-readiness checklist before installation and training are scheduled.
Delivered project and ownership
Installation, training, warranty, service, and parts
The exact scope is confirmed in writing for the selected equipment, customer location, site readiness, and commercial agreement.
Installation and startup
Confirm unloading, placement, connections, startup, test work, acceptance, travel, exclusions, and customer responsibilities.
Operator training
Confirm audience, duration, controller and machine functions, safety boundaries, materials, applications, and follow-up needs.
Warranty
Confirm warranty term and start date, covered components, exclusions, consumables, labor, travel, shipping, diagnostics, and claim process.
Service and parts
Confirm remote diagnostics, on-site service, parts identification, consumables, escalation, scheduling, pricing, and geographic availability.
Frequently asked questions
Questions to resolve before ordering
How do I confirm this machine is suitable for my parts?
Send the material, maximum thickness or capacity, part dimensions, drawings, production volume, quality requirements, and sample expectations with the quote request.
What electrical and utility information is required?
Provide voltage, phase, available amperage, panel information, compressed air, process gas, extraction, cooling, floor space, and access details.
What is included with the machine?
The written quotation separates included equipment, starter consumables, optional equipment, freight, installation, training, and customer-provided items.
How are delivery, installation, and training handled?
The project plan confirms delivery ZIP, unloading method, rigging and placement, site readiness, startup, test work, operator training, travel, and acceptance.
What warranty and service support applies?
The applicable written warranty and service scope identify the term, start date, components, exclusions, parts process, labor, travel, shipping, diagnostics, and escalation path.
Complete machine information Description
UmproTech 5×10 3kW Plate & Tube Fiber Laser — Budgetary Configurations
Combined sheet-and-tube fiber-laser platform for a nominal 5×10 ft sheet format and nominal 20 ft tube configuration with an 8 in chuck class. Pricing below is Budgetary / Estimated, based on current comparable Chinese-machine economics and component estimates—not on the previous retail price. Final offer requires a released configuration sheet.
| Configuration | Machine | Required 3kW water cooling | Budgetary equipment subtotal |
|---|---|---|---|
| Base Line — no automatic sheet load/unload; no tube bundle loader | $120,200 | $3,490 | $123,690 |
| Auto Sheet Load/Unload — sheet automation included; tube bundle loader excluded | $171,300 | $3,490 | $174,790 |
| Auto Sheet L/U + Tube Bundle Loader — both automation systems included | $222,200 | $3,490 | $225,690 |
The required cooling line is included exactly once in each subtotal. These are equipment subtotals, not turnkey installed prices.
Required application confirmation
Before order, UmproTech must confirm the released BOM and exact laser source, cutting head, controller, enclosure/interlocks, usable sheet travel, usable tube length, chuck geometry and supported profile/weight range. For automated versions, confirm magazine capacity, bundle rules, sheet-loading range, interfaces and guarding. A standard 380V three-phase / 60Hz build and the full-package load also require engineering confirmation.
Site scope
Suitable assist-gas or compressed-air delivery and fume extraction are required. Customer-site freight, unloading, rigging, foundations, facility electrical work or transformer, gas/compressor system, extraction, guarding changes, permits, field-service travel and sales tax are excluded unless specifically listed in the signed quotation.
Availability must be reconfirmed for the selected build. No physical stock quantity, warehouse location or guaranteed dispatch date is represented here.
Budgetary price validity: 14 days. Existing orders, warranties and accepted contractual obligations are unchanged.
Pricing revision: 2026-11-02 / RUN-20261102-0743-PT (R2 validation; selected prices unchanged).