Cutting Control Component
Confirm with salesXC3000S Fiber Cutting Control System — Interface Options
Review the exact configuration, utilities, included equipment, options, delivery, installation, training, warranty, service, and parts pathway for this machine.
Final equipment, accessories, freight, taxes and field-service scope are confirmed in the written quote.
Material, geometry, capacity, production volume, quality, and workflow.
Model, controller, source or drive, tooling, included equipment, and options.
Power, air, gas, extraction, cooling, access, unloading, and placement.
Delivery, startup, training, warranty, service, parts, and acceptance.
Buyer fit
Match the machine to the real work
The best configuration depends on the actual parts, production target, available utilities, operator workflow, and complete delivered project.
Prepare these application details
- Material type, grade, thickness or capacity, dimensions, geometry, and drawings.
- Prototype, mixed job-shop, repeat production, automation, and throughput expectations.
- Required finish, accuracy, repeatability, tooling, consumables, and downstream work.
- Current voltage, phase, amperage, compressed air, process gas, extraction, and floor space.
Machine specifications
Technical and facility planning
Review the selected machine build, utilities, included equipment, and site requirements together before ordering.
- Model
- LC04CSRTXV20D
- Machine family
- Cutting Control Component
- Working area / capacity
- Defined in the written build sheet
- Power / tonnage
- Matched after application review
- Controller and axes
- Confirmed for the selected build
- Electrical requirements
- Confirmed after site and build review
- Machine dimensions
- Defined in the written build sheet
- Machine weight
- Defined in the written build sheet
- Lead time
- Confirm with sales
Included equipment
The written quote will identify the machine, controller, source or drive system, cooling, accessories, starter items, and other included equipment.
Available options
Options are selected for automation, material handling, extraction, gas, tooling, safety, utilities, production volume, and future expansion.
Site readiness
Plan the facility before delivery
Electrical service, utilities, extraction, access, unloading, placement, commissioning, and operator preparation are part of the machine project.
- Confirm voltage, phase, amperage, breaker, disconnect, grounding, and transformer requirements.
- Confirm compressed air, process gas, extraction, cooling, drainage, and environmental requirements.
- Confirm crate dimensions, machine weight, door and aisle clearance, dock, forklift, crane, and placement path.
- Complete the site-readiness checklist before installation and training are scheduled.
Delivered project and ownership
Installation, training, warranty, service, and parts
The exact scope is confirmed in writing for the selected equipment, customer location, site readiness, and commercial agreement.
Installation and startup
Confirm unloading, placement, connections, startup, test work, acceptance, travel, exclusions, and customer responsibilities.
Operator training
Confirm audience, duration, controller and machine functions, safety boundaries, materials, applications, and follow-up needs.
Warranty
Confirm warranty term and start date, covered components, exclusions, consumables, labor, travel, shipping, diagnostics, and claim process.
Service and parts
Confirm remote diagnostics, on-site service, parts identification, consumables, escalation, scheduling, pricing, and geographic availability.
Frequently asked questions
Questions to resolve before ordering
How do I confirm this machine is suitable for my parts?
Send the material, maximum thickness or capacity, part dimensions, drawings, production volume, quality requirements, and sample expectations with the quote request.
What electrical and utility information is required?
Provide voltage, phase, available amperage, panel information, compressed air, process gas, extraction, cooling, floor space, and access details.
What is included with the machine?
The written quotation separates included equipment, starter consumables, optional equipment, freight, installation, training, and customer-provided items.
How are delivery, installation, and training handled?
The project plan confirms delivery ZIP, unloading method, rigging and placement, site readiness, startup, test work, operator training, travel, and acceptance.
What warranty and service support applies?
The applicable written warranty and service scope identify the term, start date, components, exclusions, parts process, labor, travel, shipping, diagnostics, and escalation path.
Complete machine information Description
Configure your fiber-cutting controls around the Raytools XC3000S series. Choose the interface used by your machine and whether the package requires the EDS2010 I/O expansion module.
Choose your configuration
- EtherCAT Connection — EDS3000 Standard Set.
- EtherCAT Connection — EDS3000 Standard Set+EDS2010.
- Pulse Connection — EDS3000 Standard Set.
- Pulse Connection — EDS3000 Standard Set+EDS2010.
Package reference
The supplier's packing illustration lists an EPC-2000 embedded controller, an EDS3000 I/O module, a wireless handheld control, a TTA preamplifier, a control cable, three Ethernet cables, a sensor cable, a dongle and a rectifier diode. EDS2010 is the optional I/O module selected by the “Standard Set+EDS2010” option. Confirm the final bill of materials, board revisions and software entitlement in the UmproTech quotation. An external HMI computer, servo drives and cutting head shown in connection diagrams are application components, not confirmed package contents.
Reference dimensions
| Component | Approximate inches | Original metric reference |
|---|---|---|
| EPC-2000 | 5.276 × 5.000 × 1.890 in | 134 × 127 × 48 mm |
| EDS3000 I/O module | 12.559 × 5.079 × 1.063 in | 319 × 129 × 27 mm |
| EDS2010 I/O module — optional | 7.362 × 4.961 × 1.043 in | 187 × 126 × 26.5 mm |
| Wireless handheld control | 7.244 × 3.110 × 0.984 in | 184 × 79 × 25 mm |
| TTA preamplifier | 1.732 × 1.535 × 1.102 in | 44 × 39 × 28 mm |
Dimensions follow the axes marked in the supplier's photographs. Inch values are rounded conversions using 25.4 mm per inch; use the original metric dimensions and the confirmed revision drawing for mounting and clearance checks.
Integration check
The source specification lists 12V DC for EPC-2000 and 24V DC for EDS-3000. These are component requirements, not a mains-input rating for a complete system. Confirm the power supplies, wiring, servo interface, I/O assignments, height-control hardware and software version for your installation. EtherCAT and pulse options are not interchangeable without checking the machine. The supplier shares package photographs between the two interfaces; photographs do not establish identical internal hardware or compatibility.
Ordering through UmproTech
Confirm the selected configuration, final UmproTech price, delivery terms and warranty in your quotation. Software licenses, installation and retrofit services are included only when expressly listed.