Cutting Nozzle
Confirm with salesRaytools 3D M8 Cutting Nozzles
Review the exact configuration, utilities, included equipment, options, delivery, installation, training, warranty, service, and parts pathway for this machine.
Final equipment, accessories, freight, taxes and field-service scope are confirmed in the written quote.
Material, geometry, capacity, production volume, quality, and workflow.
Model, controller, source or drive, tooling, included equipment, and options.
Power, air, gas, extraction, cooling, access, unloading, and placement.
Delivery, startup, training, warranty, service, parts, and acceptance.
Buyer fit
Match the machine to the real work
The best configuration depends on the actual parts, production target, available utilities, operator workflow, and complete delivered project.
Prepare these application details
- Material type, grade, thickness or capacity, dimensions, geometry, and drawings.
- Prototype, mixed job-shop, repeat production, automation, and throughput expectations.
- Required finish, accuracy, repeatability, tooling, consumables, and downstream work.
- Current voltage, phase, amperage, compressed air, process gas, extraction, and floor space.
Machine specifications
Technical and facility planning
Review the selected machine build, utilities, included equipment, and site requirements together before ordering.
- Model
- LN03PNC05
- Machine family
- Cutting Nozzle
- Working area / capacity
- Defined in the written build sheet
- Power / tonnage
- Matched after application review
- Controller and axes
- Confirmed for the selected build
- Electrical requirements
- Confirmed after site and build review
- Machine dimensions
- Defined in the written build sheet
- Machine weight
- Defined in the written build sheet
- Lead time
- Confirm with sales
Included equipment
The written quote will identify the machine, controller, source or drive system, cooling, accessories, starter items, and other included equipment.
Available options
Options are selected for automation, material handling, extraction, gas, tooling, safety, utilities, production volume, and future expansion.
Site readiness
Plan the facility before delivery
Electrical service, utilities, extraction, access, unloading, placement, commissioning, and operator preparation are part of the machine project.
- Confirm voltage, phase, amperage, breaker, disconnect, grounding, and transformer requirements.
- Confirm compressed air, process gas, extraction, cooling, drainage, and environmental requirements.
- Confirm crate dimensions, machine weight, door and aisle clearance, dock, forklift, crane, and placement path.
- Complete the site-readiness checklist before installation and training are scheduled.
Delivered project and ownership
Installation, training, warranty, service, and parts
The exact scope is confirmed in writing for the selected equipment, customer location, site readiness, and commercial agreement.
Installation and startup
Confirm unloading, placement, connections, startup, test work, acceptance, travel, exclusions, and customer responsibilities.
Operator training
Confirm audience, duration, controller and machine functions, safety boundaries, materials, applications, and follow-up needs.
Warranty
Confirm warranty term and start date, covered components, exclusions, consumables, labor, travel, shipping, diagnostics, and claim process.
Service and parts
Confirm remote diagnostics, on-site service, parts identification, consumables, escalation, scheduling, pricing, and geographic availability.
Frequently asked questions
Questions to resolve before ordering
How do I confirm this machine is suitable for my parts?
Send the material, maximum thickness or capacity, part dimensions, drawings, production volume, quality requirements, and sample expectations with the quote request.
What electrical and utility information is required?
Provide voltage, phase, available amperage, panel information, compressed air, process gas, extraction, cooling, floor space, and access details.
What is included with the machine?
The written quotation separates included equipment, starter consumables, optional equipment, freight, installation, training, and customer-provided items.
How are delivery, installation, and training handled?
The project plan confirms delivery ZIP, unloading method, rigging and placement, site readiness, startup, test work, operator training, travel, and acceptance.
What warranty and service support applies?
The applicable written warranty and service scope identify the term, start date, components, exclusions, parts process, labor, travel, shipping, diagnostics, and escalation path.
Complete machine information Description
UmproTech offers this Raytools 3D nozzle family in two body sizes and four listed constructions. Select the complete size, construction and bore combination; each option is a separate part, not a set of all shown nozzles.
| Listed body size | Approx. diameter × height | Construction | Listed bores, mm |
|---|---|---|---|
| D12 H10 M8 | 0.472 × 0.394 in (12 × 10 mm) | Single layer | 0.5, 0.8, 1.0, 1.2, 1.5 |
| D15 H19 M8 | 0.591 × 0.748 in (15 × 19 mm) | Single layer; single layer chrome plated; double layer chrome plated | 0.8, 1.0, 1.2, 1.5, 1.6, 1.8, 2.0, 2.3, 2.5, 3.0, 3.5, 4.0 per construction |
There are 41 listed combinations: five D12 H10 parts and 36 D15 H19 parts. The source also calls this family E Type. Raytools is retained as the recorded manufacturer/vendor; UmproTech identifies the storefront and supply service.
Bore reference
Approximate inch equivalents: 0.0197 in (0.5 mm), 0.0315 in (0.8 mm), 0.0394 in (1.0 mm), 0.0472 in (1.2 mm), 0.0591 in (1.5 mm), 0.0630 in (1.6 mm), 0.0709 in (1.8 mm), 0.0787 in (2.0 mm), 0.0906 in (2.3 mm), 0.0984 in (2.5 mm), 0.1181 in (3.0 mm), 0.1378 in (3.5 mm) and 0.1575 in (4.0 mm). Only combinations offered in the selector apply. Metric dimensions remain the reference.
Fit and specification checks
M8 is the listed metric thread designation, not an inch-thread conversion; thread pitch is not specified. The D12 H10 source photo has an M14 arrow while its specification panel, option and separate detail sheet state M8. Thread fit for the five D12 variants requires confirmation before release. For Double Chrome, the source gallery panel repeats the SCP code used for Single Chrome, while the separate detail sheet identifies DCP; that model-label discrepancy remains recorded for confirmation. Neither inconsistency has been silently corrected.
Compare the installed head, original nozzle drawing, thread, body dimensions, construction and bore before ordering. The two body sizes are not interchangeable by assumption. Photos show the source-mapped construction, with example bore markings such as 1.0 retained; they do not depict every bore at its exact opening size.
UmproTech supply terms
The selected nozzle is the item under review. Cutting heads, ceramics, other accessories and multi-piece presentation boxes shown in supplier material are not included unless specified in the final offer. Final UmproTech price, package quantity, dispatch lead time and applicable warranty terms must be confirmed before release.