CW Cutting Source
Confirm with salesRaycus Multi-Module CW Laser Sources — 4–15 kW
Review the exact configuration, utilities, included equipment, options, delivery, installation, training, warranty, service, and parts pathway for this machine.
Final equipment, accessories, freight, taxes and field-service scope are confirmed in the written quote.
Material, geometry, capacity, production volume, quality, and workflow.
Model, controller, source or drive, tooling, included equipment, and options.
Power, air, gas, extraction, cooling, access, unloading, and placement.
Delivery, startup, training, warranty, service, parts, and acceptance.
Buyer fit
Match the machine to the real work
The best configuration depends on the actual parts, production target, available utilities, operator workflow, and complete delivered project.
Prepare these application details
- Material type, grade, thickness or capacity, dimensions, geometry, and drawings.
- Prototype, mixed job-shop, repeat production, automation, and throughput expectations.
- Required finish, accuracy, repeatability, tooling, consumables, and downstream work.
- Current voltage, phase, amperage, compressed air, process gas, extraction, and floor space.
Machine specifications
Technical and facility planning
Review the selected machine build, utilities, included equipment, and site requirements together before ordering.
- Model
- FLS01RFLC4000MHP
- Machine family
- CW Cutting Source
- Working area / capacity
- Defined in the written build sheet
- Power / tonnage
- Matched after application review
- Controller and axes
- Confirmed for the selected build
- Electrical requirements
- Confirmed after site and build review
- Machine dimensions
- Defined in the written build sheet
- Machine weight
- Defined in the written build sheet
- Lead time
- Confirm with sales
Included equipment
The written quote will identify the machine, controller, source or drive system, cooling, accessories, starter items, and other included equipment.
Available options
Options are selected for automation, material handling, extraction, gas, tooling, safety, utilities, production volume, and future expansion.
Site readiness
Plan the facility before delivery
Electrical service, utilities, extraction, access, unloading, placement, commissioning, and operator preparation are part of the machine project.
- Confirm voltage, phase, amperage, breaker, disconnect, grounding, and transformer requirements.
- Confirm compressed air, process gas, extraction, cooling, drainage, and environmental requirements.
- Confirm crate dimensions, machine weight, door and aisle clearance, dock, forklift, crane, and placement path.
- Complete the site-readiness checklist before installation and training are scheduled.
Delivered project and ownership
Installation, training, warranty, service, and parts
The exact scope is confirmed in writing for the selected equipment, customer location, site readiness, and commercial agreement.
Installation and startup
Confirm unloading, placement, connections, startup, test work, acceptance, travel, exclusions, and customer responsibilities.
Operator training
Confirm audience, duration, controller and machine functions, safety boundaries, materials, applications, and follow-up needs.
Warranty
Confirm warranty term and start date, covered components, exclusions, consumables, labor, travel, shipping, diagnostics, and claim process.
Service and parts
Confirm remote diagnostics, on-site service, parts identification, consumables, escalation, scheduling, pricing, and geographic availability.
Frequently asked questions
Questions to resolve before ordering
How do I confirm this machine is suitable for my parts?
Send the material, maximum thickness or capacity, part dimensions, drawings, production volume, quality requirements, and sample expectations with the quote request.
What electrical and utility information is required?
Provide voltage, phase, available amperage, panel information, compressed air, process gas, extraction, cooling, floor space, and access details.
What is included with the machine?
The written quotation separates included equipment, starter consumables, optional equipment, freight, installation, training, and customer-provided items.
How are delivery, installation, and training handled?
The project plan confirms delivery ZIP, unloading method, rigging and placement, site readiness, startup, test work, operator training, travel, and acceptance.
What warranty and service support applies?
The applicable written warranty and service scope identify the term, start date, components, exclusions, parts process, labor, travel, shipping, diagnostics, and escalation path.
Complete machine information Description
Choose a Raycus HP-series continuous-wave fiber laser source for integration into cutting equipment. The five models are separate configurations; select the exact model and revision required by your machine. Manufacturer: Raycus.
Model and installation references
| Model | Output | Reference W × H × D |
|---|---|---|
| RFL-C4000M-HP | 4 kW | Approx. 35.433 × 38.583 × 42.913 in (900 × 980 × 1090 mm) |
| RFL-C6000M-HP | 6 kW | Approx. 35.433 × 38.583 × 42.913 in (900 × 980 × 1090 mm) |
| RFL-C8000M-HP | 8 kW | Approx. 35.433 × 38.583 × 42.913 in (900 × 980 × 1090 mm) |
| RFL-C12000M-HP | 12 kW | Approx. 47.244 × 38.583 × 45.669 in (1200 × 980 × 1160 mm) |
| RFL-C15000M-HP | 15 kW | Obtain the revision-specific installation drawing before layout approval |
The supplier dimension table includes casters and lifting rings but excludes the warning light. These are planning references, not mounting dimensions. Confirm the supplied revision and space for cooling connections, controls and fiber routing. For 15 kW, published depths differ: approximately 45.669 in (1160 mm) in the supplier sheet versus 43.937 in (1116 mm) on the Raycus page; neither is adopted as the final installation dimension.
Optical, cooling and electrical configuration
- Reference wavelength: 1080±5 nm; CW/modulated operation and water cooling.
- Delivery fiber reference: approximately 65.62 ft (20 m) for 4/6 kW, and 98.43 ft (30 m) for 8/12/15 kW. Length is configuration-dependent.
- Reference operating temperature: 50–104 °F (10–40 °C).
Confirm the exact optical connector before matching a cutting head. Documentation uses HQBH for 4/6 kW and QD for higher powers; the 15 kW manufacturer page also lists QP. These labels do not establish interchangeability. Electrical input also requires revision confirmation: the supplier table lists 360–510 V AC, 50/60 Hz, while the Raycus 4 kW page lists 340–420 V AC, three-phase four-wire, 50/60 Hz. Confirm the nameplate and control protocol; these sources are not specified here as 240 V single-phase equipment.
Freight planning
The supplier packing table distinguishes net from gross weight: 6 kW approximately 705.5/1075.9 lb (320/488 kg); 8 kW 806.9/1124.4 lb (366/510 kg); 12 kW 1016.3/1472.7 lb (461/668 kg); 15 kW 1309.5/1752.7 lb (594/795 kg). These are reference packing figures, not a confirmed shipment. Obtain current crate dimensions and weights; 4 kW packing weight remains unconfirmed.
Selected source and included items
The listing is for one selected source. Confirm delivery fiber, power/serial/network cables, connector inserts, cooling hoses and adapters in the final bill of materials. The detailed supplier packing list is specifically labeled RFL-C15000M-HP and is not a common kit for all five models. A chiller, cutting head, installation and commissioning are separate unless included in the UmproTech quotation. Current gallery images represent the 4 kW and 6 kW configurations only.
UmproTech price, delivery, warranty, exact revision and integration requirements must be confirmed before release. Model names and factory markings identify Raycus equipment; UmproTech is the seller.